Every clear aligner plan starts with records. The software, the lab and any colleague you ask for a second opinion all work from what you send them. If the photos are angled, the scan has gaps or the bite is wrong, the plan is built on a flawed picture of the patient.
This checklist covers the photographs and digital scans most clinicians collect before aligner treatment, how to take them consistently, and the errors that most often cause problems later. It is written for dentists and orthodontists in Pakistan who are building a routine for their clinic, whether they are on their first case or their fiftieth.
Why record quality matters
Records do three jobs. They support the diagnosis, they let you and the planning team design tooth movements, and they give you a baseline to compare against at every review and at the end of treatment. They are also your documentation if a patient later questions the result.
Photographs are useful, but they have limits. In a study of orthodontists' diagnostic accuracy, molar and canine classification judged from ideal, standardised intraoral photographs was not reliably accurate, and accuracy fell significantly as the camera angle moved away from ideal (Jackson et al., 2019). The authors concluded that intraoral photographs alone may not be enough to judge occlusal relationships such as Angle classification and midlines.
Two practical points follow:
- Standardise your photo angles, because small changes in angle change what the photo seems to show.
- Use photos together with a clinical examination and an accurate model of the teeth, not as a replacement for them.
The photo set: a standard checklist
Most clinicians use a set of extraoral and intraoral views. The exact set varies between clinics and planning providers, so check what your provider asks for. A common baseline is:
Extraoral photos
- Frontal at rest: lips relaxed, head upright, eyes looking straight ahead.
- Frontal smiling: a natural full smile that shows how much tooth and gum are displayed.
- Profile (right side): head in a natural position, lips relaxed.
- Oblique smile (optional): a three-quarter view, helpful for smile and incisor display.
Intraoral photos
- Frontal in occlusion: teeth together, cheek retractors in place, camera centred on the midline.
- Right and left buccal in occlusion: camera square to the canine and molar region, so the buccal relationships can be seen.
- Upper occlusal: taken with a mirror, showing the full arch.
- Lower occlusal: taken with a mirror, with the tongue kept back.
- Overjet view (optional): a side view of the incisors to show overjet and overbite.
Take the same set, in the same order, for every patient. A fixed routine is easier for staff to learn and makes progress photos directly comparable with the start.
Camera or smartphone?
Many clinics in Pakistan use a DSLR with a macro lens and ring flash. Others use a smartphone. A recent in vivo study compared professional DSLR cameras with flagship smartphones using a standardised workflow that included gray-card colour calibration and optical zoom (Yuan et al., 2026). Under that workflow, smartphone photos achieved colour accuracy and dimensional consistency comparable to the DSLR cameras. The DSLR cameras still had advantages in demanding aesthetic cases.
The key word is standardised. Whatever you use:
- Keep the same distance, zoom and lighting for each view.
- Use the phone's optical zoom rather than moving very close with a wide lens, which distorts the teeth.
- Use consistent lighting, such as a ring light or the clinic's photography setup.
- Consider a gray card or similar reference if colour matters for the case.
- Avoid filters, beauty modes and automatic "enhancement" settings.
Also think about where the photos are stored. Patient photos on a personal phone and in messaging apps are a privacy risk. Move them to a secure clinic record and remove them from the device.
Photo technique tips
- Prepare the patient: remove lipstick, clean the teeth, and dry the surfaces with air so saliva does not reflect the flash.
- Use clean, warm retractors: pull the cheeks outwards and slightly forwards, not just backwards, so the buccal teeth are visible.
- Check the angle: for the frontal view, the occlusal plane should be level and the camera centred on the midline. For buccal views, use a retractor or mirror to see the molars squarely.
- Use mirrors well: warm the mirror to avoid fogging, and keep the whole arch in view, including the last molars.
- Review before the patient leaves: look at every image at full size. Retaking a blurred photo now takes a minute; recalling the patient takes a week.
The digital scan checklist
Most aligner providers now accept intraoral scans, and many prefer them. For scanner types and what to compare before buying, see our guide to intraoral scanners for aligner work.
On measurement accuracy, a systematic review of 17 studies found that orthodontic measurements on digital models were comparable to those on plaster models, with differences that were minor and clinically insignificant, although the quality of the evidence varied (Fleming et al., 2011). In practice, the accuracy of a scan depends heavily on how it is taken.
Before you send a scan, check:
- Full arches: every tooth is captured, including the distal surfaces of the last molars.
- No holes or gaps: especially at contact points, gingival margins and the palate near the teeth.
- Gingiva included: a few millimetres of gum around each tooth, which the planning software uses to define tooth crowns.
- No artefacts: cheeks, tongue or cotton rolls are not merged into the model.
- Correct bite: the buccal bite scans are taken with the patient in their usual closed position, and the arches meet the same way they do in the mouth.
- Restorations and attachments: existing composite, crowns and brackets are captured clearly, because they affect aligner fit.
If you take conventional impressions instead, check them for tears, bubbles, drag and distortion, and send the bite registration with them.
Radiographs and other records
Photos and scans do not show the roots or the bone. Depending on the case, clinicians usually add:
- An OPG to check roots, missing or unerupted teeth, and bone levels.
- A lateral cephalogram when the skeletal pattern or incisor inclination affects the plan.
- Periapical or other views where a specific tooth needs closer assessment.
Radiograph decisions should follow your clinical findings and local radiation protection practice, not a fixed rule. Our clear aligner patient checklist covers the wider set of pre-treatment checks.
Common record errors
- Buccal photos taken at an angle, which make a Class II molar look Class I, or the other way round.
- Missing distal surfaces of second molars on the scan.
- An open or shifted bite on the scan that does not match the patient's real occlusion.
- Saliva, fog or flash reflections hiding the details you need.
- Different photo set-ups at the start and at review, so progress cannot be judged.
- Records taken weeks before a restoration, extraction or other change in the mouth.
Many tracking problems that appear mid-treatment trace back to an early record error. If you are reviewing a case that is not tracking, it is worth going back to the original records first. Our article on mid-course correction for tracking issues covers what to look for.
Progress and final records
Use the same photo set and scan protocol at key review points, before a refinement, and at the end of treatment. Matching records make it easier to see what moved as planned and what did not. Final records are also the reference for retention. For more on that stage, see retention after aligner therapy.
Quick checklist before you submit a case
- Full photo set taken, in your standard order and angles.
- Every image reviewed at full size before the patient leaves.
- Full-arch scans with no gaps, artefacts or missing molars.
- Bite checked against the patient's real occlusion.
- Radiographs chosen according to the clinical findings.
- Clinical notes, diagnosis and treatment goals written down.
- Records stored securely in the clinic system, not on a personal device.
Training and mentorship
Good records are a skill that improves with feedback. If you want help setting up a records routine for your clinic, or reviewing your first cases with an experienced clinician, FOAP can arrange training and mentorship on request. Fill in the FOAP form and our team will contact you with the next steps.
References
- Jackson TH, Kirk CJ, Phillips C, Koroluk LD. Diagnostic accuracy of intraoral photographic orthodontic records. Journal of Esthetic and Restorative Dentistry. 2019. doi:10.1111/jerd.12426
- Yuan J, Cui J, Ma H, Li X, Li S. Comparison of accuracy and reliability between smartphone and digital single-lens reflex camera in clinical dental photography: an in vivo study. Clinical Oral Investigations. 2026. doi:10.1007/s00784-026-07025-0
- Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthodontics & Craniofacial Research. 2011. doi:10.1111/j.1601-6343.2010.01503.x
This article is for dental professionals and is not a substitute for clinical judgment or formal training.