Using TADs with Clear Aligners

A gloved finger points at a 3D dental CBCT scan shown on a tablet

Aligners hold the whole arch together, so every tooth that moves pushes back on the others. For simple alignment that hardly matters. For large retraction, molar distalization or vertical changes, it decides whether the plan on the screen becomes the result in the mouth.

Temporary anchorage devices (TADs), usually miniscrews placed in the alveolar bone or palate, give you a fixed point that does not move in response. This article explains when they are worth adding to an aligner case, what recent studies report, and what to plan for before you place one. It does not favour any aligner or miniscrew brand.

Why aligner cases run short of anchorage

With aligners, the teeth you do not want to move are the anchorage. Attachments and Class II or Class III elastics help, but elastics take their anchorage from the other arch and bring their own side effects, such as incisor proclination or extrusion. They also depend entirely on the patient wearing them.

A miniscrew sidesteps both problems. It is not a tooth, so it does not move in response to force, and it works whether or not the patient remembers elastics. Our article on managing anchorage in aligner orthodontics covers the wider picture; this one focuses on miniscrews.

What the evidence says

Overall picture

A systematic review of 14 studies on aligners combined with miniscrews concluded that the combination improved control in demanding movements, especially intrusion, extrusion and distalization. The authors also listed the practical difficulties: miniscrews must be placed precisely, and insertion can be uncomfortable. Patients were generally satisfied, mostly because of the comfort and appearance of the aligners (Marinelli et al., 2025). Much of the underlying evidence is case reports and small series, so treat this as support for the idea rather than a set of fixed rules.

Incisor retraction in extraction cases

A retrospective CBCT study looked at adults whose upper premolars were extracted and treated with aligners. Cases were grouped by anchorage: no TADs, TADs in the posterior region only, or TADs both anteriorly and posteriorly. Both TAD groups achieved more lingual movement of the upper central incisors than the group without TADs. The vertical result differed sharply: only the group with anterior and posterior TADs intruded the incisors, while the other two groups showed incisor extrusion. Every group retroclined the incisors by more than ten degrees. The combined anterior and posterior group also had more apical root resorption, and the amount of intrusion was the strongest predictor of resorption (Zhang et al., 2026).

Two points follow for practice. Posterior TADs help hold the molars during space closure, but they do not stop the incisors from deepening the bite. And intruding retracted incisors is a real gain that carries a real cost to the roots. Plan for both, and read our article on root resorption with aligners before taking on these cases. For broader planning of extraction cases, see extraction cases with clear aligners.

Whole-arch distalization

A small French cohort of 24 adults compared miniscrew-supported distalization with aligners and with fixed appliances. Neither group was clearly better on the main outcomes. The upper incisors moved back in both groups, and the change was significant only with aligners. The authors judged that aligners gave more incisor retraction but less molar distalization than fixed appliances, which they linked to the way the aligner holds the teeth together and to the flexibility of the material. The authors suggested that good attachment design and extending the aligner further over the crowns may help, and they said that control of incisor tipping with aligners is still unproven (Brière et al., 2026).

If your goal is true molar distalization, do not assume that adding a miniscrew will deliver it. Check the planned molar movement, the attachments on the molars and premolars, and the direction of the elastic from the screw.

Anterior open bite

A systematic review and meta-analysis compared aligners with fixed appliances supported by TADs for anterior open bite. Aligners closed the bite mainly by extruding the incisors and did not significantly intrude the molars. Fixed appliances with TADs gave greater overbite correction and more upper molar intrusion. Results with aligners stayed stable during retention in the included studies (Charoenrat et al., 2026).

The comparison was between aligners and TAD-supported fixed appliances, so it does not tell you how well aligners combined with miniscrews intrude molars. What it does show is that molar intrusion is not something aligners achieve reliably on their own. If an open bite needs posterior intrusion rather than incisor extrusion, skeletal anchorage is worth discussing. Our article on open bite and deep bite cases with aligners covers the diagnosis.

When to consider TADs in an aligner case

  • Maximum anchorage extraction cases, where molars must not drift forward during incisor retraction.
  • Retraction that needs vertical control of the incisors, so that the bite does not deepen.
  • Distalization of a full quadrant or arch, especially when elastics alone have not worked or the patient cannot wear them.
  • Posterior intrusion for open bite or for levelling over-erupted molars.
  • Asymmetric problems, such as a one-sided Class II, where elastics would affect both sides.

If none of these applies, a miniscrew may add cost and discomfort with little gain.

Planning before you place

  • Decide the force direction first. The site of the screw and the attachment point on the aligner, usually a button or a cut-out, determine the line of force. Draw it on the setup before choosing the site.
  • Image the site. A panoramic radiograph is the minimum. Where roots are close together or the palate is involved, a CBCT helps you avoid roots and assess bone.
  • Tell the lab or planner. The setup must include the cut-outs, buttons and staging that the miniscrew needs, and the planned tooth movement must match what the screw is meant to do.
  • Plan the timing. Decide in which aligner stage the screw is loaded and when elastics or chains are added.
  • Set realistic vertical goals. Intrusion with TADs works, but it raises the risk of root resorption. Check roots on a radiograph during treatment.

Placement, risks and consent

Miniscrew placement is a surgical procedure. Place them only if you are trained to do so, or refer to a colleague who is. Before treatment, discuss with the patient:

  • discomfort during and shortly after insertion;
  • the chance that a screw loosens or fails and needs replacing;
  • soft tissue irritation and the need for careful cleaning around the head;
  • a small risk of contact with a root, and the plan if it happens;
  • the possibility of extra root resorption when teeth are intruded.

Record this discussion in the notes, as you would for any procedure.

Monitoring during treatment

At each visit check the screw for mobility, the tissue around it for inflammation, and the aligner for full seating at the attachment point. If the aligner is lifting near the button, the force may be pulling it off the teeth rather than moving them. Compare progress with the setup and refine early if the anchorage is not behaving as planned.

Training and mentorship

Combining miniscrews with aligners joins two skill sets, and many dentists find it helpful to plan the first few cases with an experienced colleague. FOAP can arrange training and mentorship on request. Fill in the FOAP form and our team will contact you with the next steps.

References

  1. Marinelli G, Inchingolo AM, Inchingolo AD, Ferrante L, Avantario P, Campanelli M, Palermo A, Inchingolo F, Dipalma G. Temporary anchorage devices in clear aligner therapy: a systematic review. Bioengineering. 2025. doi:10.3390/bioengineering12050531
  2. Zhang X, Wang Z, Ren R, Li D, Zheng W, Mei L, Li Y. Treatment outcomes of different TAD patterns in clear aligner therapy for maxillary incisor retraction after premolar extraction. European Journal of Orthodontics. 2026. doi:10.1093/ejo/cjag060
  3. Brière E, Ellouze S, Gebeile-Chauty S. Miniscrew-assisted arch distalization: a comparative cohort study of aligners and multi-bracket appliances. L'Orthodontie Française. 2026. doi:10.1684/orthodfr.2026.245
  4. Charoenrat T, Uengkajornkul P, Changsiripun C. Incisor extrusion with or without molar intrusion for the correction of anterior open bite with clear aligners and comparison of outcomes with fixed appliances incorporating temporary anchorage devices: a systematic review and meta-analysis. Korean Journal of Orthodontics. 2026. doi:10.4041/kjod25.064

This article is for dental professionals and is not a substitute for clinical judgment or formal training.

Redefining Pakistani Smiles,
Pioneering Aligner Excellence in Pakistan

Become a member